Wingate 검사 시 Warm-up에 따른 무산소성 운동능력 차이
안의수1, 김종규2
1성균관대학교
2한국체육대학교
Difference of anaerobic ability in warm-up 0 and 100watt at Wingate test
ABSTRACT
Ahn, E.S., Kim, J.K. Difference of anaerobic ability in warm-up 0 and 100watt at Wingate test. Exercise Science, 16(3): 281-290, 2007. The purpose of this study was to investigate effect of anaerobic power on warm-ups with 0watt(W1) and 100watt(W2) in WAnT. Twenty-six professional cyclists who is registered with the Cycle Racing Corporation, participated in four tests for two weeks to measure WAnT. On each day, the test lasted for 30 seconds as a workload of 0.7%(4.41J). The result of W2(p<.05) showed significantly higher rate in PP, MP and MP/kg when W1 and W2 were compared. But there was not significantly in PP/kg, TPP, and FI between W1 and W2. Results of errors between warm-up(0watt) and warm-up(100watt) of W1 and W2 errors of PP(14.51%), PP/kg(7.26%) showed higher rate than those of the MP(13.84%) and MP/kg(6.26%). On the Lactic acid values test W1 showed significantly higher rate than W2 at the recovery time of 2min and 20min(p<.05). Anaerobic contribution and lactate recovery ratio were showed that W1 was higher significantly than W2. Therefore, we can conclude that wam-up load which is used in WAnT, makes difference in PP(7.26%) and MP(6.26%), and it also has an effect on alteration of recovery period.
Key words: WAnT, warm-up, PP, MP, error
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
  • Download Citation  Download Citation
    Download Citation
    Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

    Format:
    • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
    • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
    Include:
    • Citation for the content below
    Difference of anaerobic ability in warm-up 0 and 100watt at Wingate test
    Exerc Sci. 2007;16(3):281-290.
    Close
  • Share:      
    METRICS
    0
    Crossref
    0
     
    2,317
    View
    13
    Download
    Related articles
    Determination of Anaerobic Capacity - Reliability and Validity of Sprint Running Tests  2020 May;29(2)
    Effects of anaerobic power in warm-up revolutions per minute on WAnT  2008 February;17(1)
    Editorial Office
    The Korean Society of Exercise Physiology
    Dept. of Healthcare and Science, Dong-A University, 37, Nakdong-daero 550beon-gil, Saha-gu, Busan 49315, Korea
    Tel: +82-10-4019-0208, +82-51-200-7517   E-mail: editor@ksep-es.org
    Editorial Assistant: Taewan Kim +82-10-4019-0208
    About |  Browse Articles |  Current Issue |  For Authors and Reviewers
    Copyright © The Korean Society of Exercise Physiology.                 Developed in M2PI